<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Parameter Archive - Velamed Medizintechnik</title>
	<atom:link href="https://velamed.com/tag/parameter/feed/" rel="self" type="application/rss+xml" />
	<link>https://velamed.com/tag/parameter/</link>
	<description>Biomechanische Labore, Messsysteme und Messlösungen</description>
	<lastBuildDate>Thu, 16 Oct 2025 12:33:59 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>Neuer Balance Parameter in MR3 (Time to Boundary TTB)</title>
		<link>https://velamed.com/time-to-boundary-ttb/</link>
		
		<dc:creator><![CDATA[Velamed Team]]></dc:creator>
		<pubDate>Fri, 08 Jul 2022 13:31:44 +0000</pubDate>
				<category><![CDATA[Allgemein]]></category>
		<category><![CDATA[Noraxon Sprunganalyse]]></category>
		<category><![CDATA[Boundary]]></category>
		<category><![CDATA[Formel]]></category>
		<category><![CDATA[Parameter]]></category>
		<category><![CDATA[Sprung]]></category>
		<category><![CDATA[Stand]]></category>
		<category><![CDATA[Time]]></category>
		<guid isPermaLink="false">https://www.velamed.com/?p=15352</guid>

					<description><![CDATA[<p>­ Der Parameter Time to Boundary ist ein relativ neuer Parameter und dient dazu, Aussagen zur Stabilität im Stand zu treffen. Bisher konnten wir in MR3 die Bewegungen des Center of Pressure, wie in Abb. 1 dargestellt vollautomatisch berechnen. Berechnung Der neue Parameter Time to Boundary wird mithilfe einer Formel berechnet und reagiert sensitiver auf&#8230;</p>
<p>Der Beitrag <a href="https://velamed.com/time-to-boundary-ttb/">Neuer Balance Parameter in MR3 (Time to Boundary TTB)</a> erschien zuerst auf <a href="https://velamed.com">Velamed Medizintechnik</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>­</p>
<hr />
<h2>Der Parameter</h2>
<p><strong>Time to Boundary ist ein relativ neuer Parameter und dient dazu, Aussagen zur Stabilität im Stand zu treffen</strong>.</p>
<p><a href="https://velamed.com/wp-content/uploads/2022/07/COP-Verlauf.png"><img decoding="async" class="alignleft wp-image-25521 size-full" src="https://velamed.com/wp-content/uploads/2022/07/COP-Verlauf.png" alt="COP-Verlauf" width="250" height="180" data-wpmflightbox="1" data-wpmf_image_lightbox="https://velamed.com/wp-content/uploads/2022/07/COP-Verlauf.png" /></a></p>
<p>Bisher konnten wir in MR3 die Bewegungen des Center of Pressure, wie in Abb. 1 dargestellt vollautomatisch berechnen.</p>
<h2 style="clear: both;">Berechnung</h2>
<p>Der neue Parameter Time to Boundary wird mithilfe einer Formel berechnet und reagiert sensitiver auf Schwankungen des Center of Pressure, da neben räumlichen Parametern auch zeitliche Parameter für die Berechnung verwendet werden.</p>
<h3><strong>TTB(i)= d(i) / Vcp(i)</strong></h3>
<p><a href="https://velamed.com/wp-content/uploads/2022/07/Time-to-boundary.png"><img decoding="async" class="alignright wp-image-25522" src="https://velamed.com/wp-content/uploads/2022/07/Time-to-boundary-172x400.png" alt="Time to Boundary" width="129" height="300" data-wpmflightbox="1" data-wpmf_image_lightbox="https://velamed.com/wp-content/uploads/2022/07/Time-to-boundary.png" srcset="https://velamed.com/wp-content/uploads/2022/07/Time-to-boundary-172x400.png 172w, https://velamed.com/wp-content/uploads/2022/07/Time-to-boundary.png 215w" sizes="(max-width: 129px) 100vw, 129px" /></a><strong>time(sec)=distance(mm) / velocity(mm/sec)</strong></p>
<p><strong>d(i)</strong>:  distance between instantaneous position of either the anterior-posterior or medio-lateral COP and the anterior-posterior or medio-lateral stability boundary datapoint (i)</p>
<p><strong>Vcp(i)</strong>: instantaneous velocity of the COP in either anterior-posterior or medio-lateral direction</p>
<p><strong>Time-to-boundary: </strong>combination of velocity and distance from the stability boundary</p>
<p><strong>→</strong><strong> spatio-temporal information about the control behaviour</strong></p>
<h2>Auswertung der Daten</h2>
<p>Bei der Auswertung der Daten muss beachtet werden, dass geringe Zeitwerte für eine geringe Time to Boundary stehen und damit einen instabilen Stand signalisieren. Diese Minimalwerte werden ausgewertet (Abb. 2).</p>
<p><a href="https://velamed.com/wp-content/uploads/2022/07/Datenauswertung-TtB.png"><img fetchpriority="high" decoding="async" class="aligncenter wp-image-25523 size-full" src="https://velamed.com/wp-content/uploads/2022/07/Datenauswertung-TtB.png" alt="Datenauswertung TtB" width="434" height="317" data-wpmflightbox="1" data-wpmf_image_lightbox="https://velamed.com/wp-content/uploads/2022/07/Datenauswertung-TtB.png" srcset="https://velamed.com/wp-content/uploads/2022/07/Datenauswertung-TtB.png 434w, https://velamed.com/wp-content/uploads/2022/07/Datenauswertung-TtB-400x292.png 400w" sizes="(max-width: 434px) 100vw, 434px" /></a></p>
<p><strong>Der Parameter TTB wird zukünftig als Reportelement vollautomatisch berechnet und dargestellt.<br />
</strong></p>
<hr />
<h4><strong>Literatur: </strong></h4>
<p>Hertel et al. (2005) Deficits in time-to-boundary measures of postural control with chronic ankle instability<br />
Van Wegen et al. (2002) Postural orientation: Age-related changes in variability and time-to-boundary</p>
<hr />
<p><strong><em>Sprungseminar:</em></strong></p>
<p><em><a href="https://velamed.com/seminare#Seminare">www.velamed.com/seminare</a></em></p>
<p>Der Beitrag <a href="https://velamed.com/time-to-boundary-ttb/">Neuer Balance Parameter in MR3 (Time to Boundary TTB)</a> erschien zuerst auf <a href="https://velamed.com">Velamed Medizintechnik</a>.</p>